Kits
Individual Items
Custom


High-quality standalone components for customizing and optimizing your microfluidic workflows

Semi–Permeable Capsule Kits
SPC Generation Kit (Flux)
Designed for
Single-cell isolation into SPCs on the Flux system
Includes
Microfluidic chips, oils, SPC generation and release reagents, additional components
Runs
Up to 8 samples with ~200,000 SPCs generated per chip lane
Size
80 µm
SPC Innovator Kits (Onyx)
Designed for
Single-cell isolation into SPCs on the Onyx microfluidic platform
Includes
Microfluidic chips, oils, SPC generation and release reagents, additional components
Runs
Up to 6 samples
Size
30 - 300 µm
Microfluidic Kits
Droplet Generation Kits
Designed for
Partitioning samples into water-in-oil droplets (one aqueous inlet) using the Onyx microfluidic system
Includes
Microfluidic chip, oils, syringes, tubing and additional components
Runs
Up to 6 samples, each capable of at least 2 hours of run-time
Size
25 - 55 µm
Co-Flow Droplet Generation Kits
Designed for
Partitioning samples into water-in-oil droplets (two aqueous inlets) using the Onyx microfluidic system
Includes
Microfluidic chip, oils, syringes, tubing and additional components
Runs
Up to 6 samples, each capable of at least 2 hours of run-time
Size
30 - 65 µm
Reagent Addition Kit
Designed for
Reagent addition into water-in-oil droplets using the Onyx microfluidic system
Includes
Microfluidic chip, oils, syringes, tubing and additional components
Runs
Up to 3 samples, each capable of at least 2 hours of run-time
Size
Reinjected: 25 - 40 µm;
Post-addition: 30 - 50 µm.
Droplet Merging Kit
Designed for
Pairwise water-in-oil droplet merging using the Onyx microfluidic system
Includes
Microfluidic chip, oils, syringes, tubing and additional components
Runs
Up to 3 samples, each capable of at least 2 hours of run-time
Size
Reinjected: 25 - 30 µm; Generated on-chip: 40 - 45 µm; Post-merging: 40 - 50 µm.
Droplet Selection Kit
Designed for
Fluorescence activated droplet sorting using the Styx microfluidic system
Includes
Microfluidic chips, spacing oil, tubing and additional components
Runs
Up to 5 samples, capable of at least 4 hours of run-time
Size
25 - 100 µm
Microfluidic Chips
Droplet Generation Chips
Material
PDMS
Designed for
Partitioning samples into water-in-oil droplets (one aqueous inlet)
Runs
Up to 6 samples, each capable of at least 2 hours of run-time
Size
18 - 110 µm
Co-Flow Droplet Generation Chips
Material
PDMS
Designed for
Partitioning samples into water-in-oil droplets (two aqueous inlets)
Runs
Up to 6 samples, each capable of at least 2 hours of run-time
Size
30 - 65 µm; 160 - 200 µm;
Reagent Addition Chips
Material
PDMS
Designed for
Reagent addition into water-in-oil droplets
Runs
Up to 3 samples, each capable of at least 2 hours of run-time
Size
Reinjected: 25 - 30 µm;
Post-addition: 30 - 50 µm.
Droplet Merging Chips
Material
PDMS
Designed for
Droplet Selection Chips
Material
PDMS
Designed for
Fluorescence activated droplet sorting
Runs
1 sample, capable of at least 4 hours of run-time
Size
25 - 100 µm
Oils
Droplet Stabilization Oil
Designed for
Stabilizing emulsions during the generation of water-in-oil droplets
Quantity
15 mL of ready-to-use solution
Droplet Spacing Oil
Designed for
Maintaining consistent spacing between water-in-oil droplets during reinjection
Quantity
15 mL of ready-to-use solution
Sample Loading Oil
Designed for
Eliminating dead volume by displacing all aqueous solutions in the syringe
Quantity
15 mL of ready-to-use solution
Emulsion Breaker
Designed for
Disrupting water-in-oil emulsions to recover encapsulated samples
Quantity
1 mL of ready-to-use solution
Accessories
Safe needles
Description
Capped needles with pre-attached microfluidic tubing
Designed for
Ensuring safe and hassle-free syringe connection to microfluidic chips
Quantity
50 units
Microfluidic Tubing
Description
PTFE Tubing (1.07mm OD x 0.56mm ID)
Designed for
Seamless connection with Atrandi’s microfluidic chips
Quantity
30m

Publications Referencing Our Products
A high-throughput multiparameter screen for accelerated development and optimization of soluble genetically encoded fluorescent biosensors
Read publication
Neurog3-Independent Methylation Is the Earliest Detectable Mark Distinguishing Pancreatic Progenitor Identity
Read publication
Single Distal Mutation Enhances Activity of known PETases via Stabilisation of PET-binding
Read publication
Hydrop enables droplet-based single-cell ATAC-seq and single-cell RNA-seq using dissolvable hydrogel beads